CLINITEK Status® Connect SystemNeed more control over your point-of-care urinalysis testing process?

CLINITEK Status® Connect System simplifies wireless or wired connectivity and testing oversight in point-of care urinalysis for improved risk management.

  • Offers flexible connectivity solutions by integrating data directly to the LIS, EMR or via point-of-care data management software solutions
  • Provides improved POC testing workflow efficiencies when interfaced to leading data management solutions
  • New 2-D bar-code scanner — for the DCA Vantage® Analyzer and CLINIITEK Status® Connect System
  • Improves risk management through advanced operator control functions, prevents unauthorized use
  • Drives compliance across testing sites with programmable QC protocols and QC lockout
  • Auto-Checks* help to ensure the quality and accuracy of data while facilitating an enhanced interpretation of results.

Features & Benefits

Eliminates error sources

  • Accurately times test for you—no watching the clock!
  • Automates and removes subjectivity of results interpretation and reduces error rate.1
  • Automatically transmits test results to minimize transcription errors (when interfaced).1
  • Offers 2D and linear bar-code data entry for patient ID, operator ID, and test and QC lot information to minimize transcription errors.

Improves data integrity 

  • Proprietary Auto-Checks® technology:
    • Prevents false-positive results if test strip integrity is compromised by humidity overexposure.
    • Ensures that only validated Siemens Healthineers test strips are used to test patient samples.
  • Operator lockout prevents use by unauthorized users.
  • Quality control (QC) management prevents testing if QC fails or is not followed.

Provides interfaced solutions 

Assays

 

Test Parameters

 

SG

pH

Protein

Protein  Low

Glucose

Ketone

Leukocyte

Bilirubin

Uro-Bilinogen

Nitrite

Blood

Albumin

Creatinine

Other

 Urine Test Strips

CLINITEK® Microalbumin 2

X

X

A:C ratio

Hema-Combistix®

X

X

X

X

Multistix® 10 SG

X

X

X

X

X

X

X

X

X

X

Multisix® 5

X

X

X

X

X

Multistix® 7

X

X

X

X

X

X

X

Multistix® 8 SG

X

X

X

 

X

X

X

X

X

Multistix PRO® 10 LSP*

X

X

X

X

X

X

X

X

X

X

P:C ratio

Uristix®1

X

X

Uristix® 41

X

X

X

X

Other Tests

CLINITEST® hCG

hCG

1

Technical Specifications

Semi-quantitative Tests Measured

 

Routine urine tests

blood, bilirubin, glucose, ketone, leukocytes, nitrite, 
pH, protein, specific gravity and urobilinogen

Kidney disease test

albumin, creatinine, albumin-to-creatinine ratio

Pregnancy test

Human Chorionic Gonadotropin (hCG)

General Specifications

 

Depth

10.7 in. or 27.2 cm

Width

6.7 in. or 17.1 cm

Height

7.5 in. or 18.5 cm

Weight

5.0 lbs or 2.3 kg

Electrical rating

100V - 240V AC, 50-60 Hz (with in-line lead)

Battery operation

Not available

Ambient temperature range

18 to 30ºC (64 to 86ºF)

Humidity range

18-80% relative humidity, non-condensing

Compliance

UL, CE, EMC

Calibration

automatic, self-calibrating

Communication Capabilities

 

Auto-Checks™ Technology

Identify strip types, simplifying training and operation

Detect humidity exposure, ensuring data quality

Quality Control Management Features

QC testing and reporting

QC reminders or mandatory prompt

QC lockout

Barcode Data Entry

Patient ID, operator ID and name, QC control type, lot number, and expiration date

Bar-code Symbology Supported

Code 39 (with and without check digit), Code 93, Code 128, 
Codabar and Interleaved 2 of 5 (with and without check digit) 
and two dimensional (2-D) data matrix or aztec bar-codes

Operator Security Features

Define up to 700 operators

Operator lock-out to prevent unauthorized use

Customize access level for each operator for the following functions:

  • Performing patient tests
  • Performing QC tests
  • Recalling results
  • Modifying system settings

Communication Capabilities

 

Communication protocol

HL7, POCT1-A2

Data transmission options

wireless, Ethernet or serial connection

Interfaces with leading point-of-care data management solutions***

  • Siemens’ RAPIDComm® Data Management and Connectivity Solution
  • MAS RALS®-Plus
  • Telcor Quick-Linc®
  • Conworx Technology POCcelerator™

Memory

Patient test results

700

QC test results

200

Operator IDs

700

Auto-Checks™ Technology

Identify strip types, simplifying training and operation

Detect humidity exposure, ensuring data quality

Quality Control Management Features

QC testing and reporting

QC reminders or mandatory prompt

QC lockout

Barcode Data Entry

Patient ID, operator ID and name, QC control type, lot number, and expiration date

Bar-code Symbology Supported

Code 39 (with and without check digit), Code 93, Code 128, 
Codabar and Interleaved 2 of 5 (with and without check digit)
 and two dimensional (2-D) data matrix or aztec bar-codes

Operator Security Features

Define up to 700 operators

Operator lock-out to prevent unauthorized use

Customize access level for each operator for the following functions:

  • Performing patient tests
  • Performing QC tests
  • Recalling results
  • Modifying system settings

Subscription Button Icon
Be the first to know about our events, training, and news